beautypg.com

Power consumption measurement – NEXCOM NISE 3520 User Manual

Page 109

background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

96

NISE 3520 Series User Manual

Appendix A: Power Consumption

Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
PROVA CM-07 AC/DC CLAMP METER

Device Under Test
DUT: Sys #1 / Sys #2

Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Run the Intel Kpower program.
5. Run the LAN Packet Counter and Receive program.

Test Data

Sys #1

Sys #2

+19V

+19V

Full-Loading Mode

2.97A

3.42A

Total

56.43W

64.98W

Standby Mode

1.025A

0.94A

Total

19.475W

17.86W

This manual is related to the following products: