2 c5/9 controller technical specifications, C5/9 controller technical specifications – KLING & FREITAG K&F ACCESS T9 User Manual
Page 25
![background image](https://www.manualsdir.com/files/769516/content/doc025.png)
User’s Manual
ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2009
Version 6.0, 17.03.2009
Page 25 of 60
8.1.2
C5/9 Controller Technical Specifications
Input
Nominal + 6 dB
+20 dB maximum level
20k
Ω galvanically insulated
XLR connectors ( Pin 2 + )
Outputs
Nominal +6 dB (+1.55 V) electronically balanced
XLR connectors ( Pin 2 + )
Control output + 15 Volt
Gain
Variable, -
∞ dB to +6 dB
Sense
Galvanically insulated
Speakon 4-pin
Dynamic range
>116 dB
THD ( THD+N )
< 0.02%
LED displays
Clip
Signal -40 dB, 0 dB, +10 dB
Bass Sense (GREEN ) / Limit ( RED )
Mid Excursion Limit, Sense (GREEN), Limit (RED)
High Sense (GREEN) / Limit (RED)
Power
Switches
Front
Single / Cluster
Normal / High Boost
Level
Rear
Ground Lift
Voltage Selector
8.1.3
Pin Diagrams of the C5/9 Controller's In- and Outputs
I
N
P
U
T
LINK
3
1
2
2
1
3
O
U
T
U
HIGH
T
P
L
I
T
F
3
1
2
MID
BASS
2
3
1
2
1
3
LINK
S
E
N
S
E
BASS
HIGH + MID
Made in
READ MANUAL BEFORE USE
50-60Hz / 30VA
115 / 230VAC
T 500 / T 315mA
CONTROLLER K&F ACCESS C5/9
SEND (+15 V)
POWER SEQUENCE
Fuse 115 / 230V:
Power Requirements:
Serial Number:
Germany
KLING
&
FREITAG GmbH
2
3
0
115
SELECTOR
VOLTAGE
SENSE BASS
SENSE / LINK
HIGH + MID
OUTPUT
BASS / MID / LOW
+
-
+ MT
+ HT
- MT
- HT
INPUT / LINK
parallel
parallel
SEQUENCE (
+ 15V)
2
3
1
-
+
1
3
2
-
+
1-
2-
1+
2+
IN
1-
2-
1+
2+
IN