4 specification of the fuses, Specification of the fuses – KLING & FREITAG K&F ACCESS T9 User Manual
Page 14
User’s Manual
ACCESS SYSTEM
KLING & FREITAG GMBH ©1995-2009
Version 6.0, 17.03.2009
Page 14 of 60
4.1.4
Specification of the Fuses
The fuses in all models have the following identical specifications:
Bussmann S 506
Bussmann S 506
Bussmann S 506
Bussmann S 506----8A slow
8A slow
8A slow
8A slow
When necessary, these fuses may only be replaced with the aforementioned original fuse.
4.1.5
Replacement and Positions of the Short-Circuit Fuses
When the fuse is blown, then the chassis is most likely already ruined, as the fuse just
prevents consequential damage resulting from a short circuit of the chassis.
A disassembly of the chassis is, therefore, unavoidable.
The fuse holder of the subwoofers is mounted on the signal wiring behind the input
connector. The ACCESS subwoofers have 2 fuses; one for each of the parallel operating
chassis.
When replacing the fuse, the lid of the terminal with the signal connectors must be
screwed off to reach the fuse holder.
Warning