8 remote control, Gpi remote control (parallel remote) – Junger Audio d07 - Digital Transmission Processor User Manual
Page 11
A 2 –Installation
The digital audio toolbox b40 can be remote-controlled by means of parallel
GPI contacts.
use :
remote-controlled changeover of presets
connector:
D-SUB 15pin, female
Pin assignment of the connector :
Pin
Signal name
Functions
1
GPI1 in
Defined by d07 config
2
GPI2 in
Defined by d07 config
3
GPI3 in
Defined by d07 config
4
GPI4 in
Defined by d07 config
5
GPI5 in
Defined by d07 config
6
GPI6 in
Defined by d07 config
7
GPI7 in
Defined by d07 config
8
GPI8 in
Defined by d07 config
9
+ 5V
110
Ω
10
GPI1/GPI2 common
11
GPI3 common
12
GPI4 common
13
GPI5 common
14
GPI6 common
15
GPI7/GPI8 common
Shield
GND
Electrical specification:
GPI input
potential free by opto-coupler in line with
a current source
ON: +3.5…+30V between GPIx input
and GPx common
OFF: less then 1.5V between GPIx input
and GPIx common
For serial numbers S/N 182 and higher (HW Revision 2 and higher) the
polarity of the GPI inputs has been changed. to make use of the internal
ground based
auxiliary 5 V for "low active" switching.
ON: -3.5…-30V between GPIx input
and GPx common
OFF : less then 1.5V betwee GPIx input
and GPIx common
Signal duration must be at least 50msec.
Note : An internal auxiliary voltage feed of +5V is available on pin 9
via a 110
Ω
resistor. Ground is available from the shield of the connector
only! When using the auxiliary voltage feed, there is no electrical isolation
given anymore and the risk to inject unwanted noise is high!
Important Note :
You must take care about the polarity of the external
voltage applied to the GPIs.
Wrong polarity
may
destroy electronic
components
and may
cause fire
inside the d07!
2.8
REMOTE
CONTROL
2.8.1
GPI REMOTE
CONTROL
(PARALLEL
REMOTE)