beautypg.com

C8491, C8000, Digital audio modular processing system – Junger Audio C8491 - Compact Card User Manual

Page 9

background image

digital audio
modular
processing system

C8000

3G/HD/SD-SDI – DSP 4/8/16 audio channels

C8491

page

9/21


OVERVIEW/SETUP

This page shows the function blocks which are available for the respective programs. The display
depends on the program configuration of the DSPs. Below an example where DSP 1 is configured for
4 x 2 while DSP 2 is configured for 5.1 + 2 program processing:

SDI Bypass

[Off / On]

You may bypass the audio de-embedder / embedder for testing or
trouble shooting purposes.

Relay Bypass

[Off / on]

The main SDi pass from SDI IN to SDI OUT 1 has a power fail
bypass relay. The relay may be turned off manually for testing or
trouble shooting purposes.

Relay Wait Time

[3 … 60 seconds]

After Power Up

In order to have the DSP operational and all module function block
up and running before processing starts you may delay the moment
of switching on the signal path by x amount of seconds.

Stream Select (3G-B)

[Stream 1 / Stream 2]

For 3G-B SDI operation (see SMPTE 372 for details) you must
select which of the two streams runs through this particular module.

SNMP: Input Lost

the monitoring of the physical SDI input can be disabled for the
SNMP agent to prevent unwanted traps if the module is frequently
taken out of service.