C8082, C8000, Digital audio modular processing system – Junger Audio C8082 - Switch Over / Ducker User Manual
Page 4: Switch over & ducking

digital audio
modular
processing system
C8000
switch over & ducking
C8082
Jünger Audio Studiotechnik GmbH
Justus-von-Liebig-Strasse 7
D -12489 Berlin
Germany
phone: +49-30-677721-0
fax:
+49-30-677721-46
[email protected]
www.junger-audio.com
4/19
location of switches:
dip-switch settings
Since this type of module has an electronic output routing facility, great care must be taken when installing
or exchanging a module!
NO LABEL:
ON
CAN address range is extended by +16 (counting from 0x10 to 0x1F)
OFF
CAN address range is standard (counting from 0x0 to 0xF) see rotary
encoder settings below.
REMOTE:
must be ON
BUS-EN:
ON
Connects the outputs to the C8k audio buses on power up automatically.
The output configuration will be taken from the NV (non volatile) memory.
OFF
Disconnects the module outputs from the C8k buses on power up.
Important note! To avoid audio bus conflicts when you replace a module or install an additional one and
the configuration is unknown, the output bus drivers must be disabled by BUS-EN=OFF before inserting it.
If all settings are done remotely and the unit fits into the bus assignment scheme of a frame, you must
remove it and place the switch back into position BUS-EN=ON.
TDM:
must be OFF