beautypg.com

DekTec DTE-3114 IP to 4x QAM User Manual

Page 50

background image

DTE-3114 – Networked Quad QAM Modulator

USER MANUAL

50

List of status codes:
1 - Modulation standard is invalid
2 - QAM mode is invalid
3 - Symbol rate is out of range
4 - Interleaver I is out of range
5 - Interleaver J is out of range
6 - Frequency is out of range
7 - Overall spectrum cannot be wider than 32 Mhz
8 - Channel frequencies must increase monotonically
9 - RF level is out of range
10- Modulation standards are not equal for all channels
11- QAM modes are not equal for all channels
12- Spectral inversion settings are not equal for all channels
13- Symbol rates are not equal for all channels
14- Interleaver settings are not equal for all channels
15- Combination of interleaver I and J is invalid
16- RF-level range is too wide
17- Spectrum overlaps spectrum of another channel
18- SMPTE settings are not consistent"
::= { outEntry 12 }


---------------------------------------------------------------------------
-- DTE Alarm Traps --
---------------------------------------------------------------------------

trRfLevelError NOTIFICATION-TYPE
OBJECTS { almRfAlarmValue }
STATUS current
DESCRIPTION
"RF output level error. The difference between the device's target
RF level (the sum of channel RF levels) and the measured RF level
exceeds 'almRfAlarmValue'."
::= { traps 1 }

---------------------------------------------------------------------------
-- Object Groups --
---------------------------------------------------------------------------
--
devAlarmGroup OBJECT-GROUP
OBJECTS { almRfAlarmValue,
almRfAlarmEnable }
STATUS current
DESCRIPTION
"A collection of objects providing RF alarm information."

::= { groups 1 }

devOutputGroup OBJECT-GROUP
OBJECTS { outNumberOfOutputs,

outIndex,

outNwRxIndex,
outPhysicalPort,
outFrequency,
outSymbolRate,
outModulationStandard,
outQamMode,
outSpectralInversion,
outInterleaverI,
outInterleaverJ,
outRfLevel,
outSettingsStatus
}
STATUS current
DESCRIPTION
"A collection of objects providing RF output information."

::= { groups 2 }

devAlarmTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS { trRfLevelError
}
STATUS current
DESCRIPTION
"A collection of objects providing alarm trap information."

::= { groups 3 }

---------------------------------------------------------------------------
-- END --
---------------------------------------------------------------------------
END

This manual is related to the following products: