ID

Settings error

Description / Remarks

2. Port is not valid

The selected port number is not valid (1 .. 65535).

3. IP-to-RF delay is out of range

The valid range is 0 .. 120ms.

4. Port numbers overlap

If FEC decoding is enabled for a TSoIP stream entering

the DTE-3114 on port x, then port numbers x+2 and x+4

are reserved for FEC packets and cannot be used by

other channels with the same source IP address.

5. FEC settings are not equal for all

channels

If two or more channels refer to the same TSoIP stream

(same source stream modulated on different frequencies),

then the FEC-decoding settings and IP-to-RF delays for

these channels must be equal to each other.

6. Not used

7. Modulator settings are not

consistent


Settings error related to the “Modulator Settings” webpage and DTE-QAM-MIB:

ID

Settings error

Description / Remarks

1. Modulation standard is invalid

The modulation standard is not 0 (DVB-C), 1 (J.83 Annex

B) or 2 (J.83 Annex C).

2. QAM mode is invalid

3. Symbol rate is out of range

4. Interleaver I is out of range

5. Interleaver J is out of range

6. Frequency is out of range

7. Overall spectrum cannot be wider

than 32 MHz

The difference between the highest carrier frequency and

the lowest carrier frequency may not be greater than

24MHz.

8. Channel frequencies must

increase monotonically

Channel carrier frequencies cannot be entered arbitrarily:

The frequency of the first channel must be lower than that

of the second channel, etc.

9. RF level is out of range

The output level, which is the sum of the output levels of

the four modulator channels, is outside the valid range.

10. Modulation standards are not

equal for all channels

To satisfy hardware constraints, each channel must

operate in the same QAM standard (DVB-C, …).

11. QAM modes are not equal for all

channels

Idem for QAM mode (64-QAM, …).

12. Spectral inversion settings are not

equal for all channels

Idem for spectral inversion.

13. Symbol rates are not equal for all

channels

Idem for symbol rate.

14. Interleaver settings are not equal

for all channels

Idem for interleaver settings (J.83 Annex B only).

15. Combination of interleaver I and The combination of interleaver parameters I and J is not