5.5.
Rate Graph
This area displays the total TS rate (green) and data rate (red). The data date is equal to the total TS
rate minus the rate of the null (or padding) packets:
“Data rate” = “Total TS rate” – “Null rate”.
The horizontal axis shows the time while the vertical axis shows the TS rate on a scale that is
adjusted automatically.
The TS rate and Used rate data rate) values are displayed in a tooltip if you hold the cursor above
the graph.
5.6.
Source Video Viewer
This window provides a real-time visual monitor for the input signal.
This screen will be black if there is no input signal, or no input synchronization, or if there is a
problem with the input adapter. The refresh rate of this input window depends on the complexity of
the encoding, and may be very slow for HD H264 encoding.
5.7.
Start Button
These buttons can be used to Start and Stop the encoding process.
It is recommended to Stop and Start the encoding each time a setting is changed, so to permit the