Dataman 848 User Manual
Page 9

DATAMAN 848 MANUAL
Quick Start
9
when the chips are being inserted or unloaded from
group2. After the programming of chips in group1 are
finished, the DATAMAN-848 will automatically program
the chips of group2.
A user can enable the insertion timer and adjust the
timer. Enabling the timer will allow DATAMAN-848 to
automatically shutdown a socket with poor contact upon
timeout of a user-set timer period. DATAMAN-848 then
automatically programs the chips in the remaining good
sockets. The insertion timer default setting is 5
seconds. When the insertion timer is disabled, the user
will have to either correct the insertion error or press the
ignore key to continue programming after a socket with
poor contacts is discovered.
6) DATAMAN-848 also automatically keeps a running total
of all chips that have been programmed and all chips
that have failed to program. A user can input a target
quantity of chips to be programmed and an allowable
number of programming failures. An alarm message
option provides a message to the screen alerting the
user to either the target quantity of chips being reached,
or the allowable number of failures have been reached.
7) For a detailed explanation of the device operation
options, please refer to Chapters 3 and 4.