Signal levels, Analog, Digital – Dan Dugan Sound Design E-1 User Manual
Page 19: Linking multiple dugans
Dugan Models E-1 and E-1A User Guide
Installation and Configuration
19
Signal Levels
Analog
The Model E-1A requires line level signals in the range -20 to +4 dBm; 0 dBm is optimal.
The
level
LEDs light green for normal operation and red for overload.
If there is insufficient gain to keep the
level
LEDs lit green when no one is talking, set
the rear panel
LEVEL
switch to
-10
.
Digital
Set the console input gain trimmers so program levels at the insert sends cause the
level
LEDs to remain green whether someone is talking or not.
Linking Multiple Dugans
Up to eight Dugan units can be linked into a single automatic mixing system. One
unit must be set to be the master and the others slaves.
Figure 3-6 Linking multiple Dugans
1. Designate one unit as the master by setting the NORM-SLAVE switch on the rear
panel to NORM (up).
2. Designate any other units as slaves by setting their NORM-SLAVE switches on the
rear panel to SLAVE (down).