Signal Levels

Analog

The Model E-1A requires line level signals in the range -20 to +4 dBm; 0 dBm is optimal.
The

level

LEDs light green for normal operation and red for overload.

If there is insufficient gain to keep the

level

LEDs lit green when no one is talking, set

the rear panel

LEVEL

switch to

-10

.

Digital

Set the console input gain trimmers so program levels at the insert sends cause the

level

LEDs to remain green whether someone is talking or not.

Linking Multiple Dugans

Up to eight Dugan units can be linked into a single automatic mixing system. One
unit must be set to be the master and the others slaves.

Figure 3-6 Linking multiple Dugans

1. Designate one unit as the master by setting the NORM-SLAVE switch on the rear

panel to NORM (up).

2. Designate any other units as slaves by setting their NORM-SLAVE switches on the

rear panel to SLAVE (down).