beautypg.com

Error messages – d&b D80 User Manual

Page 80

background image

15.3. Error messages
The following table lists possible error messages appearing on the

display.

Id

Error text

Eventlog text

Description

Location

Possible reasons

10

System error 8

System error 8 (%02Xh,

%d)

Unexpected CPU reset

DSP

Software or hardware

error

11

System error 128

System error 128

(%02Xh, %d)

Internal I

2

C

communication fault

DSP

Any I

2

C device defect

15

Unknown device type

Unknown device type

Unknown device type

16

Invalid device ident

Invalid device ident %d

Invalid hardware

configuration

ADDAC, Amp., SMPS

Missing or wrong

module identification

17

Invalid CPLD version

Invalid CPLD version %d

(minimum required %d)

Invalid CPLD

identification

DSP

Missing or wrong CPLD

identification

18

Invalid ADDAC ident

Invalid ADDAC board

ident %d

Invalid ADDAC

identification

ADDAC

Missing or wrong

ADDAC identification

19

Invalid display ident

Invalid display board

ident %d

Invalid DISPLAY

identification

DISPLAY

Missing or wrong

DISPLAY identification

20

Program error %u

Program error %d, %d,

%d, %d

Program error

DSP

Various

21

Invalid DSP Data

Invalid DSP database

(Position %d, Error %d)

Invalid DSP data

DSP

Software error

25

Program error %u

Program error %d: AWL

error %d in AWL %d,

line %d

Program error

DSP

Various

28

SMPS comm. error

SMPS communication

error (status %04X)

SMPS communication

fault

DSP, SMPS

DSP or SMPS defect,

cable defect

29

SMPS firmware

mismatch

SMPS firmware V%d.

%02d.%02d not suitable

for hardware ident %d

Invalid SMPS

configuration

SMPS

SMPS firmware does not

match module

identification

30

SMPS temp err %d°C

SMPS temperature error

%+3d°C (power %uw)

Temp-Off

31

SMPS overtemp %d°C

SMPS overtemperature

%+3d°C (power %uw)

SMPS overtemperature

SMPS

Poor cooling

32

Mains overvoltage %dV Mains overvoltage (avg

%3dV, peak %3dV,

status %04X, err %04X)

Mains overvoltage

(External: Mains)

Mains voltage is/was

too high

34

Mains undervoltage

%dV

Mains undervoltage

(avg %3dV, peak %3dV,

status %04X, err %04X)

Mains undervoltage

(External: Mains)

Mains voltage is/was

too low

35

SMPS error POK

SMPS error POK:

timeout while waiting for

power-ok signal %ums

(PSF %4.1uV, avg

%5.1dV)

SMPS startup timeout

SMPS

SMPS defect

36

SMPS restart error

SMPS error: too many

restarts (restart count

%d)

SMPS restart fault

SMPS

SMPS defect

d&b D80 Manual 1.9 en

80

This manual is related to the following products: