System check/lm, System check, System check/lm 10.7.1. system check – d&b D80 User Manual
Page 57

10.7. System check/LM
10.7.1. System check
System check is a powerful and convenient tool to check the
condition of a complete d&b sound reinforcement system driven by
d&b amplifiers. It is preferably used in conjunction with the d&b
Remote network and the R1 software.
However, for smaller systems or single cabinets, System check can
also be accessed and executed locally.
System check utilizes the amplifier's capability to measure the
impedance (Z) connected to its outputs using a sine wave signal
created by the DSP section of its controller.
Selecting «System check» opens the corresponding subscreen.
System check menu
The System check menu provides two buttons to start either a
«System calibration» or a «System check» run.
In addition, a table is provided indicating the progress («Status»)
and the results (Z values) for both the calibration («Calib.:») and
the check («Check:») runs.
The column header of the table for the Z values changes according
to the connected loudspeaker cabinet, provided the respective
loudspeaker setup is loaded.
Status
Brief indication of the current status of the calibration or
check process. In case of an error the status is indicated
in red.
LF
The calibration and check results for the LF section.
LF®)
The calibration and check results for the rear LF driver
of an actively driven cardioid subwoofer, such as the
J-SUB or J-INFRA.
MF
The calibration and check results for the MF section of
applicable cabinets.
HF
The calibration and check results for the HF section.
System check procedure
The typical procedure using System check is as follows:
1. When the system is fully set up, check and verify all
connections.
2. Mute all amplifier channels.
Þ The correct wiring of the system can now be tested by
listening to each channel separately using an appropriate
audio program and the MUTE switches - preferably
controlled by R1.
d&b D80 Manual 1.9 en
57