Appendix b: modbus map – CIRCUTOR AFQ Series User Manual
Page 97

AFQ-4W
Instruction Manual 97
APPENDIX B: MODBUS MAP
Name
Type
Function
Address (Hexadecimal)
Buttons
Bit
R/W
0000
Bit
Response
Description
0
0: Stop
1: Start
Start/Stop button
2
0: Rearm alarm
1: OK
Alarm reset
Name
Type
Function
Address (Hexadecimal)
Flags
Bit
R/W
0001
Bit
Response
Description
8
Harmonic filtering flag
9
Phase current balancing flag
A
Reactive current compensation flag
B
0: Priority in harmonic filtering
1: Priority in balancing and
reactive compensation
Order of priorities flag
C
Polarity alarm tripping flag
D
Low temperature alarm tripping flag
E
Resonance alarm tripping flag
Name
Type
Function
Address (Hexadecimal)
Harmonic filtering flags
Bit
R/W
0002
Bit
Description
0
Harmonic 3 filtering flag
1
Harmonic 5 filtering flag
2
Harmonic 7 filtering flag
3
Harmonic 9 filtering flag
4
Harmonic 11 filtering flag
5
Harmonic 13 filtering flag
6
Harmonic 15 filtering flag
7
Harmonic 17 filtering flag
8
Harmonic 19 filtering flag
9
Harmonic 21 filtering flag
A
Harmonic 23 filtering flag
B
Harmonic 25 filtering flag
Name
Type
Function
Address (Hexadecimal)
AFQ status
Word
R
000F
Response
0: No connection
1,2: Not initial conditions
3: Stop
4, 5, 6: Operation
7: Alarm
8: Calibration
9: Configuration