18 instruction manual getest – CIRCUTOR GETEST Series User Manual
Page 18

18
Instruction manual
Getest
ETSI EN 301 489-17
EN61000-3-2, EN61000-3-3
EMC compliancy
Device is compliant with EU LVD 2006/95/EC and EMC 89/336/EEC directives.
Due to the nature of the device, an injection of several amps will cause some
disturbance on the mains line, but EMC directive allows this disturbance in this
cases, as this phenomena is inherent to the nature of the device.
As well, depending on the quality of the mains line, mains voltage may drop a 20%
during 20ms, so it is recommended not to connect mains fluctuations sensitive
equipment to the same mains line as the MPC unit
Installation category
IEC61010 CAT III 600V
Connections
Mains: IEC320 C19 16A
Current injection : 4mm safety banana plug CATIV 600V 32A
Voltage meter: 4mm safety banana plug CATIV 600V 32A
Nota: Even when those connectors are specified for nominal currents up to 32A,
they can handle up to 150A during 20ms, without downgrading its performance or.
Protections
ICP 20A, curve D EN60898
Internal fuse F250mA
Dimensions
Size : 28.5x28.5x34cm
Weight : 45kg. Electrodes not included