5 equipment and options – BINDER FED 53 User Manual

Page 47

background image

FED (E2) 02/2015

page 47/55

Unit size

53

115

240

400

720

Ventilation data

Air change

at 70 °C / 158 °F

x/h

***

29

19

17

11

at 150 °C / 302 °F

x/h

43

32

20

18

12

at 300 °C / 572 °F

x/h

66

26

18

16

10

Electrical data
IP system of protection acc. to EN 60529

20

20

20

20

20

Nominal voltage (±10 %) 50/60 Hz

V

230 1N~ 230 1N~ 230 1N~ 400 3N~ 400 3N~

Nominal power

kW

1.20

1.60

2.70

3.40

5.00

Energy

consumption

at 70 °C / 158 °F

Wh/h

162

230

370

520

570

at 150 °C / 302 °F

Wh/h

397

544

850

1200

1320

at 300 °C / 572 °F

Wh/h

933

1100

1400

2340

2600

Unit fuse 5 x 20 mm

230V / 10A / middle-time-lag (M)

A

10 A

external

10 A

external

16 A

external

--

--

Over-current release category B

--

--

--

3 x 16A

internal

3 x 16A

internal

Power plug

shock proof plug

CEE plug 5 poles

Installation category acc. to IEC 61010-1

II

II

II

II

II

Pollution degree acc. to IEC 61010-1

2

2

2

2

2

Electrical connection data FED-UL constructed acc. to cUL standard (for USA and Canada)

Unit size

53-UL

115-UL 240-UL 400-UL 720-UL

Electrical data
Nominal voltage (±10%) 60 Hz

V

115 1N~ 115 1N~ 208 3N~ 208 3N~ 208 3N~

Power plug

NEMA

5-20P

5-20P

L21-20P L21-20P L21-20P

Nominal power

kW

1.20

1.60

2.70

3.40

5.00

Unit fuse 6,3 x 32 mm

250V / super-time-lag TT

A

16

16

16

16

20

external external

3 x

internal

3 x

internal

3 x

internal

Legend: 1) without outer glass door 2) up to 98 % of the set value
All technical data is specified for unloaded units with standard equipment at an ambient temperature of

+25 °C and a power supply voltage fluctuation of ±10. The temperature data is determined in accordance

to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of

the height, width and depth of the inner chamber. Technical data refer to 100% fan speed.
All indications are average values, typical for units produced in series. We reserve the right to

change technical specifications at any time.

If the cabinet is fully loaded, the specified heating up times may vary according to the load.

12.5 Equipment and Options

To operate the drying and heating oven FED, use only original BINDER accessories or

accessories / components from third-party suppliers authorized by BINDER. The user is

responsible for any risk arising from using unauthorized accessories.

Unit size

53

115

240

400

720

Standard equipment
Microprocessor temperature controller with LED

display and several time functions

Controller Timer functions: Delayed ON, delayed Off

and temperature dependent delayed OFF

This manual is related to the following products: