6.2 Display / entry of temperature set-point (with selected temperature ramp)
If previously a temperature ramp value has been selected (chap. 6.4.2):
Press button
in normal display / actual value display during ramp operation to have displayed the
actual temperature ramp set-point, which changes according to the selected gradient, in addition to the
entered target set-point for temperature.
The chamber is operating, the controller is in normal display (actual value
display). The
actual temperature value (example: 22 °C) is displayed:
1. Press
button
The display shows alternately “
SPr” and the actual temperature ramp set-point changing according
to the selected gradient (example: 42 °C):
This ramp set-point is displayed only, it is not adjustable.
2. Press
button
The display shows alternately “
SP” and the previous temperature set-point (example: 60 °C):
3. With the
buttons enter a set-point value between 0 and 300.
The desired temperature set-point can be selected in a temperature range from 5 °C / 9 °F
above room temperature up to 100 °C / 212 °F (BD) or 300 °C / 572 °F (ED/FD).
4. Wait 2
seconds until the entered temperature value
is
taken over
(display flashing once).
5. Press
button to return to normal display / actual value display (automatically after approx. 30
seconds).
Adjust the safety device following any changes of the set-point (chap. 7).