3.2 Single operation mode of SKP 2-00
Before installing modules, the power supply must be switched off. Ground the module acc. to EN 50083-1,
EN 60728-11:2010 in order to avoid dangerous overvoltages (attention: risk of fire/death). Use the
grounding screw attached to the device (see ã fig. 2 on page 5).
When using the SKP 2-00 in single operation mode, the power is supplied via the DC socket (see 9 in
fig. 2 on page 5). A separate power supply unit SKZ 5-00 is required for it. More units are connected by
means of the DC loop-through. One DC connection cable SKZ 4-00 is included in the delivery of the
SKP 2-00. Max. 4 pieces SKP 2-00 may be connected together in single operation mode.
Fig. 4
Assembly and connection of a single twin module
Fig. 5
Assembly and connection of up to four twin modules
In single operation mode of the SKP 2-00 the outputs of the twin cassettes must be combined together
with splitters. The splitters (SKV 2..8-00) may be used in connection with F-double sockets (CFA 3-00).
SKP
2-00
Existing distribution network
External switched-mode power
supply SKZ 5-00
SKV 2-00
Universal
Twin LNB
SKZ 4-00
4 × SKP 2-00
Existing distribution network
External switched-mode power
supply SKZ 5-00
SKV8-00
Universal
Single LNB
SKV8-00
3 × SKZ 4-00