3.2 Single operation mode of SKP 2-00

Before installing modules, the power supply must be switched off. Ground the module acc. to EN 50083-1,
EN 60728-11:2010 in order to avoid dangerous overvoltages (attention: risk of fire/death). Use the
grounding screw attached to the device (see ã fig. 2 on page 5).

When using the SKP 2-00 in single operation mode, the power is supplied via the DC socket (see 9 in
fig. 2 on page 5). A separate power supply unit SKZ 5-00 is required for it. More units are connected by
means of the DC loop-through. One DC connection cable SKZ 4-00 is included in the delivery of the
SKP 2-00. Max. 4 pieces SKP 2-00 may be connected together in single operation mode.

Fig. 4

Assembly and connection of a single twin module

Fig. 5

Assembly and connection of up to four twin modules

In single operation mode of the SKP 2-00 the outputs of the twin cassettes must be combined together
with splitters. The splitters (SKV 2..8-00) may be used in connection with F-double sockets (CFA 3-00).

SKP

2-00

Existing distribution network

External switched-mode power

supply SKZ 5-00

SKV 2-00

Universal

Twin LNB

SKZ 4-00

4 × SKP 2-00

Existing distribution network

External switched-mode power

supply SKZ 5-00

SKV8-00

Universal

Single LNB

SKV8-00

3 × SKZ 4-00