Code
Condition
solid green
no alarm, motor disabled
flashing green
no alarm, motor enabled
3 red, 1 green
(fault) drive over temp
3 red, 2 green
(fault) bad internal voltage
4 red, 1 green
(fault) supply voltage high
4 red, 2 green
(warning) supply voltage low
5 red, 1 green
(fault) over current
6 red, 1 green
(fault) open motor phase
5 red, 2 green
(warning) overload
7 red, 1 green
(warning) communication error
6 red, 2 green
(fault) bad Hall signal
7 red, 2 green
(warning) save failed
LED Error Codes
The BD drive includes red and green LEDs to indicate status. When the motor is enabled, the green LED
flashes slowly. When the green LED is solid, the motor is disabled. Conditions and errors are indicated by
combinations of red and green “flashes” as follows: