Led error codes, Contacting applied motion products, 31 stm17 hardware manual – Applied Motion STM17C-3CE User Manual
Page 31
![background image](https://www.manualsdir.com/files/766370/content/doc031.png)
LED Status & Error Codes
The STM drive+motor includes red and green LEDs to indicate status. When the motor is enabled, the green
LED flashes slowly. When the green LED is solid, the motor is disabled. Errors are indicated by combinations of
red and green “flashes” as follows:
Code
Condition
solid green
no alarm, motor disabled
flashing green
no alarm, motor enabled
1 red, 1 green
motor stall (optional encoder only)
1 red, 2 green
move attempted while drive disabled
2 red, 1 green
ccw limit
2 red, 2 green
cw limit
3 red, 1 green
drive overheating
3 red, 2 green
internal voltage out of range
4 red, 1 green
power supply overvoltage
4 red, 2 green
power supply undervoltage
5 red, 1 green
over current / short circuit
6 red, 1 green
open motor winding
7 red, 1 green
serial communication error
Contacting Applied Motion Products
Corporate Headquarters
404 Westridge Drive
Watsonville, CA 95076
(831) 761-6555
fax (831) 761-6544
31
STM17 Hardware Manual
920-0034 rev A
9/30/2010