De - deceleration, Di - distance/position, Dl - define limits – Applied Motion 1240i User Manual
Page 14: Ed - encoder dead band, Ef - encoder function
SCL Software Manual
14
920-0010 rev B
9/26/07
Affects: FC, FY, FO, FM
See also: FC, FY, FO, FM
DE – Deceleration
Changes decel setting of drive. Also allows you to request present decel setting.
Range is 1 – 3000.
Affects: FL, FS, FP, SH
See also: AC
Example:
You send
Drive sends
DE125
nothing
DE
DE=125
DI – Distance/Position
Sets or requests move distance, in steps. The sign of DI indicates move direction.
Affects: FL, FS, FP, SH, CJ
See also: AC, DE, VE
Example:
You send
Drive sends
Notes
DI20000
nothing
cw direction
DI-20000
nothing
ccw direction
DI
DI=-20000
DL – Define Limits
Sets limits to normally open (1), normally closed (2) or not used (3).
Affects: FL, FS, FP, SH, WI (jogging)
Example:
You send
Drive sends
Notes
DL1
nothing
limits are normally open
DL3
nothing
limits are not used
ED – Encoder Dead Band
On drives that have the encoder feedback option, this defines the size of the “in position” region. If
static position maintenance is enabled and a motor at rest deviates from this zone, automatic correc-
tion occurs. If “end of move correction” is turned on, and the motor is outside the dead band at the end
of a feed to length or feed to position move, automatic error correction occurs. The size is in encoder
counts.
Example:
You send
Drive sends
Notes
ED50
nothing
dead band is 50 encoder counts
ED
ED=50
EF – Encoder Function
On drives supporting encoder feedback, the EF command tells the drive what kind of position mainte-
nance you want. Static position maintenance watches the encoder while the motor is at rest. If an
external force moves the motor out of position, the drive tries to return it to within the dead band. “End
of move correction” checks the encoder position after a feed to length or feed to position move. If the