Line condition – D-Link DSL-500 User Manual
Page 58
![background image](/manuals/74602/58/background.png)
DSL-500 ADSL Router User’s Guide
Line Condition
Use the Line Condition summary window for troubleshooting problems with the ADSL connection.
Figure 5 - 29. Line Condition
ADSL State
Disconnected - ADSL connection failure
Idle - valid connection currently not active
Active - valid connection that currently transmitting packets
Data Path
Current data path type Fast or Interleaved
Protocol
Operation Mode
Modulation technique used for ADSL connection,
G.DMT or G.lite
ADSL Link Speed
Downstream/Upstream data transfer rate in Kbps
SNR
Downstream/Upstream Signal-to-Noise Ratio in dB
Link Status
ATTEN
Downstream/Upstream attenuation of signal in dB
FEC
FEC Forward Error Correction
CRC
CRC Cyclic Redundancy Control
Line Error
HEC
HEC Header Error Check
Frame Counter Number of data packets received and transmitted
Loop Distance
Loop in K ft. (range = 0 – 18 K ft.)
Use the Clear button to start a fresh session. Check the Auto-Refresh box to automatically refresh the screen.
48