Uniden BCD396XT User Manual
Page 233

233
Get/Set Battery Info
Controller → Radio
BSV [\r]
BSV,[BAT_SAVE],[CHARGE_TIME][\r]
Radio → Controller
BSV, [BAT_SAVE],[CHARGE_TIME] [\r]
BSV,OK[\r]
[BAT_SAVE]
Battery Save
(0:OFF / 1:ON)
[CHARGE_TIME]
Battery Charge Time (1-16)
< COMMAND COM >
Get/Set COM port setting
Controller → Radio
COM,[/r]
COM,[BAUDRATE],[RSV][/r]
Radio → Controller
COM,[BAUDRATE],[RSV][/r]
COM,OK[/r]
[BAUDRATE] :
OFF
:OFF
4800 :4800bps
9600 :9600bps
19200 :19200bps
38400 :38400bps
57600 :57600bps
115200:115200b
Note:
When receive “COM,OK”, next command should not be send in 2 second.
Only PC Control (Baud Rate) does not become an initial-setting value.
Clear All Memory
Controller → Radio
CLR[\r]
Radio → Controller
CLR,OK[\r]
All the memories are set for initial setting.
This command is only acceptable in Programming Mode.
Note :
It takes dozens of seconds.