Uniden BCD396XT User Manual
Page 225

225
Power OFF
Controller → Radio
POF[\r]
Radio → Controller
POF,OK[\r]
Turns off the scanner.
After this command, the scanner doesn't accept any command.
Go to quick search hold mode
Controller → Radio
QSH,[FRQ],[RSV],[MOD],[ATT],[DLY],[RSV],[CODE_SRCH],[BSC],[REP],[RSV],
[AGC_ANALOG],[AGC_DIGITAL],[P25WAITING][\r]
Radio → Controller
QSH,OK[\r] or
QSH,NG[\r]
[FRQ]
: Frequency (The right frequency)
[MOD] : Modulation
(AUTO/AM/FM/NFM/WFM/FMB)
[ATT]
: Attenuation
(0:OFF / 1:ON)
[DLY]
: Delay Time
(-10,-5,-2,0,1,2,5,10,30)
[CODE_SRCH]
: CTCSS/DCS/P25 NAC Search
(0:OFF / 1: CTCSS/DCS / 2: P25 NAC Search)
[BSC]
: Broadcast Screen
(16digit: ########・・#)
(each # is 0 or 1)
||||||||・・+- Band10
0 means OFF
|||||||| :
1 means ON
|||||||+---- Band 2
||||||+----- Band 1
|||||+------ Reserve
||||+------- NOAA WX
|||+-------- VHF TV
||+--------- UHF TV
|+---------- FM
+----------- Pager
[REP]
: Repeater Find
(0:OFF / 1:ON)
[AGC_ANALOG]
: AGC Setting for Analog Audio
(0:OFF / 1:ON)
[AGC_DIGITAL]
: AGC Setting for Digital Audio
(0:OFF / 1:ON)
[P25WAITING]
: P25 Waiting time
(0,100,200,300, .... , 900,1000)
0
: 0ms
100 : 100ms
200
: 200ms
300 : 300ms
400 : 400ms
500
: 500ms
600 : 600ms
700 : 700ms
800
: 800ms
900 : 900ms
1000 : 1000ms
[RSV]
: Reserve Parameter
* This is always only “,”.
This command is invalid when the scanner is in Menu Mode, during Direct Entry
operation, during Quick Save operation.