This command is invalid when the scanner is in Menu Mode, during Direct Entry
operation, during Quick Save operation.
FUNCTION
UASD specifies arbitrary frequency and changes to Quick Search Hold (VFO)
mode.
Parameter, such as STP, changes the contents of Srch/CloCall option.
Go to Custom search and get reception status
Controller → Radio
①
CSC,ON[\r]
②
CSC,OFF[\r]
Radio → Controller
① CSC,[RSSI],[FRQ],[SQL][\r]
CSC,[RSSI],[FRQ],[SQL][\r]
CSC,[RSSI],[FRQ],[SQL][\r]
....
....
....
CSC,[RSSI],[FRQ],[SQL][\r]
②
CSC,OK[\r]
[RSSI]
: RSSI A/D Value
(0-1023)
[FRQ]
: Current Frequency
[SQL]
: Squelch Status
(0:CLOSE / 1:OPEN)
This command outputs custom search status of each frequency sequentially.
Use CSC,OFF command to stop the output.
This command is invalid when the scanner is in Menu Mode, during Direct Entry
operation, during Quick Save operation.
*Get RSSI Level
Controller → Radio
PWR[\r]
Radio → Controller
PWR,[RSSI],[FRQ][\r]
[RSSI]
: RSSI A/D Value (0-1023)
[FRQ]
: Current Frequency
Returns current RSSI level and its frequency.
The order of the frequency digits is from 1 GHz digit to 100 Hz digit.