Step 3 – Telephone Endpoint Connection
The X16 comes standard with four RJ11 extension ports. Each port supports
up to 4 proprietary digital telephone endpoints, for a total of sixteen (16)
endpoints. Each port on the system will support up to 600 feet of cable.
In a Loop wiring or serial cable topology 600 feet is calculated by adding
the distance of the initial run plus the distance between each telephone.
Cable A to telephone 1 + (distance between telephone1 & telephone 2) +
(distance between telephone 2 & telephone 3) + (distance between
telephone 3 & telephone 4) <= 600 feet.