Ubiquiti Networks airFibe24 User Manual
Page 14
11
Chapter 2: Installation
airFiber
®
AF24 User Guide
Ubiquiti Networks, Inc.
3.
Master
Aim the Master at the Slave. If necessary, adjust
the Master’s position on the pole:
a. Loosen the Hex Nuts.
b. Adjust the Pole Mount Bracket and Pole Clamps.
c. Tighten the Hex Nuts.
Hex Nuts
Master
4.
Slave
Aim the Slave at the Master to achieve the
strongest received signal level on the Slave’s numeric
LED Display, which is located next to the Config port. If
necessary, adjust the Slave’s position on the pole.
Slave RF Power (-dBm)
Note:
Values on the LED Display are displayed
in negative (-) dBm. For example, 61 represents
a received signal level of -61 dBm. Lower values
indicate stronger received signal levels.
5.
Master
Adjust the azimuth and elevation of the Master
until the strongest received signal level is displayed on
the LED Display of the Master.
a. Sweep the Azimuth (AZ) Adjustment Bolt of the Master
through its adjustment range.
Master
Azimuth (AZ)
Adjustment Bolt
b. Sweep the Elevation (EL) Adjustment Bolt of the Master
through its adjustment range.
Master
Elevation (EL)
Adjustment Bolt
Master RF Power (-dBm)
Note:
: If the LED Display indicates an overload
condition , see ”RX Gain” on page 24
for more details about RX Gain and overload
condition.