Advanced configuration, User manual – SurgeX RP-IP-GNS User Manual
Page 12

© 2014 Electronic Systems Protection, Inc. / Technical Support: 1-800-645-9721 / espei.com Page 11
User Manual
IV.
ADVANCED CONFIGURATION:
A.
Advanced settings may be adjusted via Telnet on port 9999.
1. Upon establishing a connection, the following information is displayed:
*** ESP PCS ***
MAC address 0080A39C878F
Software version V6.9.0.3 (140902) CPK6903_XPT05
Press Enter for Setup Mode
2. To enter Setup Mode, press Enter within 5 seconds. The configuration settings display,
followed by the Change Setup menu:
enVision (EV) Mode
*** basic parameters
Hardware: Ethernet TPI
IP addr - 0.0.0.0/DHCP/BOOTP/AutoIP, no gateway
SNMP Manager not set
DHCP device name : not set
*** Security
SNMP is enabled
SNMP Community Name: public
Telnet Setup is enabled
TFTP Download is enabled
Port 77FEh is enabled
Web Server is enabled
Web Setup is enabled
ECHO is disabled
Enhanced Password is disabled
***************** Channel 1 *****************
Connect Mode : C0
Source Port : 10001
Destination Port : 00000
Destination IP : 0.0.0.0
CPU performance : Standard
Change Setup:
0 Server configuration
1 Channel 1 configuration
5 Debug
6 Security
7 factory defaults
8 exit without save
9 save and exit Your choice ?
3. Select an option on the menu by entering the number of the option in the Your choice ? field
and pressing Enter.
4. To enter a value for a parameter, type the value and press Enter, or to confirm a current
value, just press Enter.
5. Important: When you are finished, save the new configuration (option 9). The unit reboots.