Removing the blower module – StorCase Technology 14-Bay 4U SCSI Ultra320 User Manual
Page 10
InfoStation 14-Bay U320 Installation Guide - Rev. A00
StorCase Technology, Inc.
Installation
5
Figure 4: Removing the Blower Module
Captive
Screw
Module
Handle
Blower
Module
IFS14_6
Removing the Blower Module
CAUTION:
The blower module contains NO USER SERVICEABLE PARTS inside the
unit. Warranty is VOID if module is opened. Refer ALL servicing to
qualified service personnel!
WARNING:
DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These handles are
specifically designed for the installation and removal of modules only!
NOTE:
The blower module is hot-swappable. The chassis may remain on when
removing and installing the blower module.
1.
Loosen the captive pan head screw securing the blower module to the InfoStation
chassis (Figure 4).
2.
Remove the blower module by grasping handle and pulling out from chassis.
3.
To reinstall blower module, simply reverse above mentioned steps.
NOTE:
Blank plate (provided) must be installed if module slot is left empty. Instal-
lation of the blank plate is necessary for proper cooling inside chassis.