InfoStation User Interface

19

InfoStation User's Guide - Rev. A01

StorCase Technology, Inc.

The following steps show how to set-up the drive bay SCSI ID via the Display and Control Panel.

NOTE:

Press CANCEL at anytime to exit the menu system and return to the Default Display.

The menu system will automatically cancel after 15 seconds of User inactivity.

NOTE:

The drive bay SCSI ID can only be set when the drive bay is inactive (e.g. when

Drive Ready LED is OFF).

1.

Press ENTER at the Default Display so that

display = Status.

2.

Press DOWN until display = Bay Cfg.

3.

Press ENTER until display = SCSI ID.

4.

Press ENTER again until display = BAY1:0.

The drive bay can be configured only when the

SCSI ID number is blinking. If the drive bay

contains a drive or is online, SCSI ID will not blink.

5.

Press ENTER to change the SCSI ID.

The * next to the ID number indicates current

SCSI ID.

6.

Press UP or DOWN to change the SCSI ID value.

7.

Press ENTER to accept the change.

The ? indicates possible SCSI ID conflict with the

other drive bays in the same enclosure.

8.

Press UP or DOWN to scroll through each bay

and repeat steps 5-7 to change bay configura-

tion.