Rear panel – StorCase Technology 9-Bay 4U SCSI Ultra160 User Manual
Page 15

6
Introduction
StorCase Technology, Inc.
InfoStation User's Guide - Rev. A01
Rear Panel
(Figure 5)
Ultra2 (LVD) I/O Repeater Module(s) - Enhances drive signal quality. Additional
I/O repeater modules are optional, for a total of four (4) LVD channels. Refer to
Appendix B for further information.
Repeater Module LED(s) -
Error LED (Amber) - Flashing indicates a detection in either:
1. Over temperature
2. Low termination voltage
3. Invalid differential voltage
Activity LED (Green) - ON indicates that activity is present
OFF indicates that there is no activity present
Refer to the UIM or InfoMon for detailed information on repeater module status.
I/O Blank Plate(s) - May be removed when installing additional I/O Repeater
modules.
Module Handle(s) - Provide a sturdy grip for the installation and removal of the
InfoStation modules.
CAUTION:
DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These
handles are specifically designed for the installation and re-
moval of modules only!
Blower Module(s) - Dual redundant, hot swappable modules each with two (2)
high-pressure blowers inside, provide ample cooling for high speed drives (79 CFM
each module). Each module features blower fault detection, total usage hours, and
self-adjusting blowers for optimal cooling performance.
Blower Module LED(s) -
Green LED - Steady glow indicates normal blower operation.
Red LED - Flashing indicates at least one blower failure.