DE300i-S User's Guide - Rev. B00

Kingston Technology Company

Appendix B - Hot Swap Option

23

0516A

Receiving Frame
Motherboard

Hot Swap
Board

Stand Offs
(Replace Motherboard
Mounting Screws)

Remove Mounting
Screws and use to
Fasten Hot Swap Board
(2 plcs)

Carriers
Installed

Figure B-1: Installing the Hot Swap Board

Jumper Options

Most jumper options are configurable via the receiving frame motherboard (Figures 5 and 11).
The Hot Swap Board provides three configurable jumpers, DTA, DTB, and DTC (Figure B-2).
When installed (factory default), these jumpers disable on board termination at drives A, B,
and C, respectively. If a DE300 drive will be physically located at the end of a SCSI daisy
chain, remove the appropriate jumper to enable termination.

Using the Hot Swap Board

Carrier Removal

Follow the procedures below to remove the Data Express carrier from the receiving frame
equipped with the Hot Swap option.

1. Verify that the drive is not active. If the system is on a network, make certain other

users are not accessing the target drive, then disable it from the network. Dismount the
drive.

2. Turn the DE300 key/lock mechanism (located on the front of the receiving frame),

clockwise to the Off position. This unlocks the drive from the receiving frame and
activates the Hot Swap Board. The unit number on the display will begin flashing.