StorCase Technology DE200i-SWC160 User Manual
Page 13

6
Introduction
StorCase Technology, Inc.
DE200i-SWC160 User's Guide - Rev. B01
Fan Fault LED/Alarm Temporary Disable Jumper Option (Pins 17 & 18):
No Jumper (Factory Default) -
Fan Fault LED and Alarm will both function
when either fan fails.
Jumper on Pins 17 & 18-
Jumper (provided) installed will temporarily
disable both Fan Fault LED and Alarm in the
event of a single fan failure. Fan Fault LED
and Alarm will still function should the sec-
ond fan fail.
NOTE:
This jumper must be removed once the faulty fan is replaced! Refer to
Appendix D for further information.
Enable Termination Power Connector (J4): This jumper is installed at the factory
and enables termination power to/from the SCSI bus.
NOTE:
Do not remove this jumper!
Factory-Installed Jumpers (J3): There are two (2) jumpers factory-installed on J3.
One jumper is located on Pins 7 & 8, the other on Pins 9 & 10.
NOTE:
Do not remove jumpers! (Remove only if attaching the
DX1/200-SWC160/RH Isolator Board. Refer to Appendix B for further
information.)