beautypg.com

StorCase Technology DE100i-SWC160 User Manual

Page 17

background image

10

Installation

StorCase Technology, Inc.

DE100i-SWC160 User's Guide - Rev. D01

NOTE:

Option Pins 13-16 (Table 2) are used to remotely access the disk drive's motor

control options. Refer to the documentation provided by the drive manufacturer for

further information.

Open

Open

Motor spins up on "Power On"

Open

Closed

Motor spins up only if SCSI

"Start" command is received

Closed

Open

Drive motor starts spinning up

approximately 12 seconds x the

SCSI ID number for each target

drive (12 second minimum)

Closed

Closed

Reserved

Closed = Jumper installed
Open = Jumper removed

DYST

RMST

Function

1

ID0

SCSI ID

2

GND

Ground

3

ID1

SCSI ID

4

GND

Ground

5

ID2

SCSI ID

6

GND

Ground

7

ID3

SCSI ID

8

GND

Ground

9

FFAULT

Fan Fault LED/Alarm Enable

10

FFAULT

Fan Fault LED/Alarm Enable

11

SYNC

Drive Synchronous Signal

12

GND

Ground

13

RMST

Remote Start (see Table 3)

14

GND

Ground

15

DYST

Delay Start (see Table 3)

16

GND

Ground

17

Reserved Reserved

(Do Not Remove Jumper!)

18

Reserved Reserved

(Do Not Remove Jumper!)

19

FAN1

Fan 1 Power Enable

20

FAN1

Fan 1 Power Enable

21

Reserved Reserved

22

Reserved Reserved

PIN

Signal

Function

Table 1: Option Pin Connector (W1) Signal Descriptions

Table 2: Option Pins 13-16 Drive Motor Control

NOTE:

Table 1 applies to DE100i-SWC160 receiving frames Rev. B00 or higher only. Refer

to Appendix F for further information.