10
Installation
StorCase Technology, Inc.
DE100i-SWC160 User's Guide - Rev. D01
NOTE:
Option Pins 13-16 (Table 2) are used to remotely access the disk drive's motor
control options. Refer to the documentation provided by the drive manufacturer for
further information.
Open
Open
Motor spins up on "Power On"
Open
Closed
Motor spins up only if SCSI
"Start" command is received
Closed
Open
Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed
Closed
Reserved
Closed = Jumper installed
Open = Jumper removed
DYST
RMST
Function
1
ID0
SCSI ID
2
GND
Ground
3
ID1
SCSI ID
4
GND
Ground
5
ID2
SCSI ID
6
GND
Ground
7
ID3
SCSI ID
8
GND
Ground
9
FFAULT
Fan Fault LED/Alarm Enable
10
FFAULT
Fan Fault LED/Alarm Enable
11
SYNC
Drive Synchronous Signal
12
GND
Ground
13
RMST
Remote Start (see Table 3)
14
GND
Ground
15
DYST
Delay Start (see Table 3)
16
GND
Ground
17
Reserved Reserved
(Do Not Remove Jumper!)
18
Reserved Reserved
(Do Not Remove Jumper!)
19
FAN1
Fan 1 Power Enable
20
FAN1
Fan 1 Power Enable
21
Reserved Reserved
22
Reserved Reserved
PIN
Signal
Function
Table 1: Option Pin Connector (W1) Signal Descriptions
Table 2: Option Pins 13-16 Drive Motor Control
NOTE:
Table 1 applies to DE100i-SWC160 receiving frames Rev. B00 or higher only. Refer
to Appendix F for further information.