Introduction, Product range, Standard dimensions – Palram SUNLIT User Manual
Page 3: Sunlite® technical guide, Product description application

SUNLITE® Technical Guide
1
Introduction
This manual provides basic guidelines for selecting, handling and installing SUNLITE sheets. Due to their hollow core, preliminary
preparation and additional care are required before the actual installation. Please note these guidelines before starting and follow
them carefully.
Product Range
Product
Description
Application
SUNLITE®
Flat multiwall polycarbonate sheet with UV protective layer
on one side.
Suitable for both exterior and indoor applications.
SUNLITE® UV2
Flat multiwall polycarbonate sheet with UV protective layer
on both sides.
Recommended for applications that involve UV
exposure on both sides (e.g. exterior light boxes)
SUNLITE® FR
Sheet with higher fire resistance rating.
Recommended for applications in populated areas.
SUNLITE® Solar Control
Flat multiwall polycarbonate sheet with integrated metallic
reflective heat-blocking layer. The sheet that transmits less
Infrared radiation and reduces heat buildup.
Available with 25 or 30% light transmission.
SUNLITE® CL
SUNLITE® Smart
Flat multiwall polycarbonate sheet with advanced
SolarSmart™ tint that combines infrared heat blocking with a
clear view due to its high clarity.
Can be tailored to achieve different light and heat
transmissions.
SUNLITE® Plus
Flat multiwall polycarbonate sheet with anti-condensation.
Recommended for commercial greenhouses and
closed structures with an open water reservoir, such
as swimming pools.
Notes:
1. Some features of the products above can be combined. Please contact your Palram distributor for more information.
2. All the above products are supplied with a protective masking on both sides, which clearly marks the UV protected side. Protective masking on one side only is
available upon request. The masking should be removed immediately after installation.
3. For transportation, handling and storage instructions and recommendations, please refer t
.
4. SUNLITE sheets are backed by a 10 years limited warranty, available upon request.
Standard Dimensions
Structure
Thickness
(mm)
Area Weight
(Kg/m²)
U-Value
(W/m²•°K)
Width (mm)
(*USA Only)
700
980
1050 1200 1220* 1250 1600 1800 1830 2085 2090 2095 2100
Twin Wall
4
0.8
3.8
✔
✔
✔
✔
✔
✔
4.5
1.0
3.7
✔
✔
✔
✔
✔
6
1.3
3.5
✔
✔
✔
✔
✔
✔
8
1.5
3.3
✔
✔
✔
✔
✔
✔
10
1.7
2.9
✔
✔
✔
✔
✔
✔
Triple Wall
8
1.7
3.0
✔
✔
10
2.0
2.7
✔
✔
16
2.5
2.3
✔
✔
✔
✔
✔
✔
✔
✔
✔
X-Lite
16
2.5
2.1
✔
✔
✔
✔
✔
✔
✔
25
3.0
1.7
✔
✔
✔
✔
✔
✔
✔
32
3.2
1.6
✔
✔
✔
✔
✔
✔
✔
35
3.5
1.5
✔
✔
✔
✔
✔
✔
40
4.1
1.4
✔
✔
✔
V-Structure
20
2.8
1.85
✔
25
3.4
1.6
✔
32
3.6
1.5
✔
35
3.8
1.45
✔
40
4.0
1.35
✔
✔
✔
7 Walls
10
1.9
2.3
✔
✔
✔
✔
✔
✔
16
2.55
1.75
✔
✔
✔
✔
✔
✔
20
2.9
1.55
✔
✔
✔
✔
✔
✔
25
3.4
1.39
✔
✔
✔
✔
✔
✔
*Other structures, dimensions and weights are available upon request. Please contact your Palram distributor for more details.