Lcp-10g3a4edr – Delta Electronics 10GBASE-SR SFP+ Optical Transceiver LCP-10G3A4EDR User Manual

Page 14

background image

LCP-10G3A4EDR

DELTA ELECTRONICS, INC.

14 Revision:

0B

2008/9/5

www.deltaww.com

Digital Diagnostic Monitoring Interface

Alarm and Warning Thresholds (2-Wire Address A2h)

Address

#

Bytes

Name

Value (Dec.)

Unit

Note

00-01 2

Temp

High

Alarm

85 degree Celsius

02-03 2

Temp

Low

Alarm

-10 degree Celsius

04-05

2

Temp High Warning

80 degree Celsius

06-07

2

Temp Low Warning

-5 degree Celsius

1

08-09

2

Voltage High Alarm

3.6V

10-11

2

Voltage Low Alarm

3.0V

12-13

2

Voltage High Warning

3.5V

14-15

2

Voltage Low Warning

3.1V

Volt

16-17 2

Bias

High

Alarm

Iop+10 mA

18-19 2

Bias

Low

Alarm

Iop-5 mA

20-21

2

Bias High Warning

Iop+7 mA

22-23

2

Bias Low Warning

Iop-3 mA

mA 2

24-25

2

TX Power High Alarm

P +3dB

26-27

2

TX Power Low Alarm

P-3dB

28-29

2

TX Power High Warning

P +2dB

30-31

2

TX Power Low Warning

P-2dB

dBm

3

32-33

2

RX Power High Alarm

0dBm

34-35

2

RX Power Low Alarm

-13.1dBm

36-37

2

RX Power High Warning

-1dBm

38-39

2

RX Power Low Warning

-11.1dBm

dBm 4

40-45

16

Reversed

56-91

36

External Calibration Constants

92-94

3

Reversed

95

1

Checksum

5

96-97

2

Real Time Temperature

98-99

2

Real Time Supply Voltage

100-101

2

Real Time Tx Bias Current

102-103

2

Real Time Tx Optical Power

104-105

2

Real Time Rx Received Power

106-109

4

Reserved

110

1

Optional Status/ Control Bits

111

1

Reserved

112-119

8

Optional Set of Alarm and Warning

Notes:

1) T

C

: Case Operating temperature

2) I

OP

: Operating current at room temperature. The min. setting current is 0 mA.

3) P: Operating optical power of transmitter at room temperature.
4) P

0

: Overload optical power of receiver

P

S

: Sensitivity optical power of receiver

5) Byte 95 contains the low order 8bits of sum of bytes 0-94