Microlink: operator interface terminal – LINK Systems Microlink User Manual
Page 25
![background image](/manuals/739084/25/background.png)
MicroLink: Operator Interface Terminal
Manual Revision 1.0 4/20/99
B-1
APPENDIX B. ELECTRICAL SPECIFICATIONS
B.1 MicroLink / MultiSet Enclosure
Size:
11.2" wide, 7.2" high, 4" deep
Operating Temperature:
45°C (113°F) Maximum Ambient
B.2 801-1 MicroLink Logic Board
Input Power Supply:
Voltage:
115VAC ± 15VAC, 60 Hz, Single Phase
Fuse:
250 mA, Slow Blow, (5mm x 20mm)
Electromechanical Relay:
Voltage:
120VAC, 60 Hz
(or) 30VDC
Current:
5Amp Continuous (AC or DC)
B.3 801-3 Air System Control Board
Electromechanical Relay:
Voltage:
120VAC, 60 Hz
(or) 30VDC
Current:
5Amp Continuous (AC or DC)
Normally Open, Energized Closed
AC Solid State Relays:
Voltage:
120VAC, 60 Hz
Current:
1Amp Continuous
20 Amp 16ms
5 Amp 75ms
Fuse:
2 Amp Fast-Blow Picofuse
B.4 801-4 Rotary Shut Height Control Board
AC Solid State Relays:
Voltage:
120VAC, 60 Hz
Current:
1Amp Continuous
20 Amp 16ms
5 Amp 75ms
Fuse:
2 Amp Fast-Blow Picofuse
B.5 801-5 Linear Shut Height Control Board
AC Solid State Relays:
Voltage:
120VAC, 60 Hz
Current:
1Amp Continuous
20 Amp 16ms
5 Amp 75ms
Fuse:
2 Amp Fast-Blow Picofuse