Hall Research UHBX-3S User Manual
Page 7
5
© Copyright 2014. Hall Research, Inc.
All rights reserved.
UHBX-3S
By default, Output 1 of each device starts with number 1, and this number will be
incremented by one for the next output. If Output 1 is changed to 12, the Output 2 and
Output 3 will be 13 and 14 respectively.
This output channel numbering is used to transmit/receive data to or from the specified
serial receiver.
Current Connection – Allow you to view
you to view the current output connection
that the controller is connected to in
addition to the baud rate, and the parity
that the controller is communicating at with
the remote serial receiver.
Cycle HPD - This button is used to send
500ms Hot Plug Detect pulse signal to the
video source. It has the same effect of
unplugging the HDMI input cable and
plugging it back in. This forces the source
Miscellaneous
to re-initialize its HDMI video output connection (read EDID, and implement HDCP if
required).
Power Management – When it is selected, the UHBX-3S device will check for the
presence of source +5V and sink HPD. If neither +5V nor HPD is detected, the
HDBaseT extender module at the output will be in low power mode. When it is not
selected, the HDBaseT extender module at the output will always be either in Auto
or Long Reach mode.
The output video can be blanked or un-blanked
by selecting the corresponding check box.
Video Blanked
The HDBaseT output can be individually set to
either Auto or Long Reach mode.
Set HDBaseT Mode
Auto - When set to Auto, the HDBaseT
output will follow the current mode on the