2.3. Controls
The UHBX-3S Manager provides you more control and flexibility of the device than the
front panel.
The UHBX-3S creates an EDID table that the source connected to the input can read.
EDID mode can be set to either emulate or pass-thru.
Video EDID
Emulate - The internally stored EDID is
passed to the source. This EDID can be a
factory default or a learned EDID from one
of the sink LCD monitors or other device
connected to an output.
Pass-thru - The EDID passed to the source
comes from a sink LCD monitor connected to an output.
EDID Routing Modes
An EDID can be learned from a sink LCD monitor
connected to any outputs. Once, an output is
selected, just click the Learn button to learn the
EDID from the connected monitor or device.
Learn EDID
The UHBX-3S’s output can be referenced
by a number from 1 to 99, which makes
communicating to a desired remote serial
receiver easier when there are more than
one UHBX-3S devices connected in daisy
chain.
Set RS232 Start Channel