15.12 Heat Exchanger

Refer to Manual Handling section on page 65.
For access, refer to section 15.1.
Refer to section 13.3 for removal of the fan, gas valve and

burner assembly.
Drain the boiler heating circuit as described in the appropriate

section of 15.1.
Drain the boiler hot water circuit as described in the

appropriate section of 15.1.
Remove the clip securing the condense hose adapter to heat

exchanger, refer to diagram 15.7.
Pull the condense pipe adapter off the heat exchanger

connection.
Disconnect the central heating flow and return pipes from the

heat exchanger.
Move the pipes away from the heat exchanger.
Slacken the three heat exchanger securing screws and

clamps (two at the top and one at the bottom) to remove the

heat exchanger, see diagram 15.8.
CAUTION: There will be water in the heat exchanger.
Carefully ease heat exchanger out.

15.13 Flue Hood

For access, refer to section 15.1.
Remove heat exchanger as described in section 15.12.
Remove the two securing screws and pull the flue hood down

and away from the flue hood bracket and flue elbow, see

diagram 15.9.

15 Replacement of Parts

Diagram 15.9

13281

Diagram 15.8

13522

13570

Diagram 15.7