Maintenance – Glow-worm Ultimate c User Manual
Page 39
0020167175_01 - 02/13 - Glow-worm
17.6 Expansion
vessel
1
2
Key
1 Expansion
vessel
2 Expansion vessel pressure inlet
•
Check the expansion vessel's supply pressure (see « Technical
Data » chapter) by means of the pressure inlet located on the
expansion vessel. Adjust the pressure if necessary.
•
Following the installation of a new expansion vessel, fi ll and
purge the appliance or installation, if necessary.
17.7 Condensate
trap
a
Warning:
condensate is mildly acidic. Use protective gloves.
5
3
2
4
1
6
Key
1 Condensate cleaning cap
2 Condensate
pipe
3 Condensate
outletv
4 Condensate retaining screw
5 Condensate
trap
6 Hose
•
Place a container under the condensate trap (5).
•
Remove the condensate from the reservoir (1).
•
Disconnect the condensation discharge (2).
•
Disconnect the heat exchanger hose (6).
The condense trap will contain water, lift taking care not to spill
the water.
•
Remove the condensate trap (5) using the retaining screw (4).
•
Clean the hose, the trap and the siphon, remove any
accumulated dirt.
•
Reassemble the components, taking care to position the
gaskets correctly.
•
Start the siphon (3) and fi ll with water.
MAINTENANCE