Installation – Glow-worm Ultimate c User Manual
Page 21
![background image](/manuals/736826/21/background.png)
0020167175_01 - 02/13 - Glow-worm
10.4 External
accessories
e
DANGER:
Under no circumstances must any mains voltage be
applied to any of the terminals on the 24v connection
plug.
230
V
X17
RT 24V
T° ext
BUS
BUS
24 V
3
2
1
Key
1 24V room thermostat connector
2 Ebus room thermostat connector or Ebus radio receiver
3 Outdoor sensor connector
•
Fit external controls in accordance with the rules in force.
•
When installing a non eBus controller, the link fi tted to the 24V
terminals (RT/24V) must be removed.
10.5 Testing the electrical connections
Carry out preliminary electrical system checks as below:
- Resistance to earth (<1 Ohm)
- Short circuit test (L-N)
- Resistance to earth (L-E)
- Polarity check
10.3.2
230V permanent supply + 230V system controls
a
DANGER:
All cables connected to the appliance should be
permanently fi xed to the wall.
i
IMPORTANT:
This appliance will not operate without a link or system
controls fi tted.
24
V
4
5
6
7
2
1
3
Key
1 230V permanent supply
2 System
controls
3 Frost
stat
4 Main board terminal block
FP = Frost stat 230V (switchable)
RT = Switch live (230V)
= Mains earth
N = Mains neutral
L = Mains live
5 Junction
box
6 Fuse
7 Double pole connector
•
Connect the mains supply and system heating controls e.g.
room thermostat as described.
•
When installing a 230v controller, the link fi tted to the 24v
terminals (RT/24v) must be removed.
RT 24V
T° ext
BUS
INSTALLATION