beautypg.com

Glow-worm Energy Saver 80 - 100 and Gave Valve User Manual

Page 8

background image

8

221564F

2.1 Location

The boiler is not suitable for fitting outdoors.

Any electrical switch or boiler control using mains electricity
must be positioned so that it cannot be touched by a person
using a bath or shower.

The boiler must be mounted on a flat wall which is sufficiently
robust to take its weight, refer to Table 2.

2.2 Clearances

The boiler should be positioned so that at least the minimum
operational and servicing clearances are provided, see diagram
2.1.

Additional clearances may be beneficial around the boiler for
installation.

For flue installations where external access is not practicable,
consideration should be given for the space required to insert
the flue internally which may necessitate clearance larger than
those specified in diagram 2.1.

*

*

*

*

Increase to 25mm clearance from

combustible material.

Diagram 2.1

6498

5

5

200

† 600

5

5

25

200

MINIMUM CLEARANCE FROM

PERMANENT SURFACES

† A removable compartment door can be

placed at least 5mm in front of the appliance.

2 Boiler Position

Dimensions in millimetres