10.1 Safety data sheet

1 Substance/Formulation and company name
Information on the product:

Trade name of the

Glow-worm

solar fluid (item no.

0020054968)
2 Composition/Information on components
Chemical properties

Watery solution of 1.2 propylene glycol with corrosion

inhibitors
3 Possible risks
No particular risks known
4 First-aid measures
General notes:

Remove dirty clothes.
After inhaling:

Discomfort after inhaling fumes/aerosol: fresh air, help from a

doctor.
After skin contact:

Wash off with water and soap.
After eye contact:

Wash thoroughly under running water with wide open eyes for

at least 15 minutes.
After swallowing:

Rinse your mouth and then drink plenty of water.
Notes for the doctor:

Treatment of symptoms (decontamination, vital function), no

specific antidote known.
5 Firefighting measures
Appropriate extinguishing agents:

Spray, solid extinguishing agent, alcohol-fast foam, carbon

dioxide (CO

2

)

Particular hazards:

Fumes which are detrimental to health. Formation of smoke/

mist. The specified substances/substance groups may be

released in the event of a fire.
Special protective equipment for fire fighting:

Wear a breathing apparatus which is independent of the

circulating air in the event of a fire.
Further details:

The hazard depends on the combustible substances and

the fire conditions. Polluted fire water must be disposed of

according to local official regulations.

6 Measures to be taken if substances are released

accidentally
Individual-related measures:

No particular measures required.
Environmental measures:

The product may not be discharged into waters without pre-

treatment (biological sewage plant).
Cleaning/Collection methods:

Pump out the product in the event of large quantities. Absorb

small quantities with appropriate fluid bonding material.

Then dispose of them according to regulations. Rinse away

splashes with plenty of water. Inform the local water authority

in the event of large quantities which could flow into the

drainage or waters.
7 Handling and storage
Handling:

Good ventilation of the workplace, no other particular

measures required.
Fire and explosion protection:

No exceptional measures required. Cool any endangered

containers with water.
Storage:

Close containers tightly and store them at dry places. Do not

use any galvanised containers for storage.
8 Limitation of exposure and personal protective

equipment
Personal protective gear:

Hand protection: chemical-resistant protective gloves (EN

374). Suitable materials even in the event of prolonged, direct

contact (recommended: protection index 6, corresponding

to > 480 minutes permeation time according to EN 374):

flour elastomer (FKM) – 0.7 mm layer thickness. Suitable

materials for brief contact or splashes (recommended: at least

protection index 2, corresponding to > 30 minutes permeation

time according to EN 374): nitrile rubber (NBR) – 0.4 mm

layer thickness. Due to the large variety of types, observe the

instruction manuals of the manufacturer.
Eye protection:

Safety glasses with lateral protection (framed glasses) (EN

166)
General safety and hygiene measures:

Observe the usual protective measures for dealing with

chemicals.
9 Physical and chemical properties
Form: fluid

Colour: violet

Odour: product-specific

Solidification temperature: approx. -28 °C (DIN 51583)

Boiling temperature: > 100 °C (ASTM D 1120)

Flash point: none

Lower explosion limit: 2.6 % by vol. (details for

Upper explosion limit: 12.6 % by vol. 1.2 propylene glycol)

Ignition temperature: omitted

vapour pressure (20 °C): 20 mbar

Density (20 °C): approx. 1.030 g/cm3 (DIN 51757)

Water solubility: entirely soluble

Solubility (qualitative) solvent: polar solvents: soluble

pH value (20 °C): 9.0 – 10.5 (ASTM D 1287)

Viscosity, kinematic (20 °C): approx. 5.0 mm2/s (DIN 51562)

9 Solar Fluid Safety Data