7 Inspection and Maintenance

The operational reliability of the solar system may be

impaired, resulting in damge to property or personal injury, if

the inspections and maintenance work are not carried out.
The main maintenance work on the solar system and the

corresponding maintenance intervals are specified in table

7.1.

Maintenance

Maintenance interval

Solar circuit
Check the frost protection of the solar fluid (use the Glow-worm 0020054984 solar fluid tester)

Annually

Check the system pressure

Annually

Check the pH value of the solar fluid (with litmus paper, pH > 7.5)

Annually

Check the solar pump function

Annually

Bleed the system

Annually

Check the circulating volume in the solar circuit

Annually

Check the hot water thermostat mixer function

Annually

Refill with solar fluid if necessary

Annually

Check the quantity of blow-off liquid

Annually

Release the return flow preventer

Annually

Check the charge pressure of the expansion vessel

Annually

Collector
Visual inspection of the collector, collector fastenings and connections

Annually

Check whether the brackets and collector components are clean and fitted properly

Annually

Check the pipe insulation for damage

Annually

Solar control
Check the pump function (on/off, automatic)

Annually

Check the sensor temperature display

Annually

Reheating
Check the circulation pump

Annually

Check the timer/time programme settings

Annually

Reheating: does it deliver the desired deactivation temperature?

Annually

Solar cylinder
Bleed the heat exchanger if necessary

Annually

Check the connections for leaks

Annually

Check the temperature and pressure relief valve

Annually

Checking the expansion relief valve

Annually

Table 7.1 Maintenance checklist