beautypg.com

Introduction – Glow-worm Clearly Heat Pumps 5kW User Manual

Page 8

background image

0020096879_01 - 06/10 - Glow-worm

- 6 -

INTRODUCTION

16 Return heat pump temperature sensor

17 Water flow rate sensor

18 Exchanger with plates

19 Hydraulic circuit venting valve

20 Plate to plate heat exchanger temperature sensor

21 Scroll compressor

22 High pressure cooling circuit sensor

23 Liquid reservoir

24 Compressor discharge temperature sensor

25 filter

26 Pre-expansion temperature sensor

27 Electronic pressure regulator

A Heat pump flow

b Heat pump return

2.5

Hydraulic and refrigerant schematic

1

26

25

27

24

2

3

4

5

6

20

21

22

23

19

17

16

14

15

13

12

11

10

9

8

7

18

Key

1 Temperature sensor for detecting end of defrosting

2 filter

3 Ventilating fan

4 Tubular heat exchanger

5 Exterior ambient sensor

6 Air/refrigerant thermistor

7 4-way reverse cycle valve

8 Low-pressure circuit maintenance valve

9 Expansion vessel

10 High-pressure circuit maintenance valve

11 Pump

12 Compressor suction temperature sensor

13 Air trap

14 Suction accumulator

15 Outgoing heat pump temperature sensor