Side flue rear flue, 12 horizontal top flue installation – Glow-worm 30ci Plus User Manual
Page 24
24
4000123944-2
12 Horizontal Top Flue Installation
12a.1 The Horizontal Top flue - kit 86285H
Suitable for installations that require a max. flue length "L" of
740mm.
If a shorter flue length is required, the flue can be cut to a min.
length"L" of 260mm rear or 300mm side. See diagram 12a.2 for
min. flue lengths.
12a.2 Flue systems rear and side, refer to
diagram 12a.1.
12a.3 Flue cutting, refer to diagram 12a.3.
Important: Do not leave any burrs or sharp edges on the cut
ends of the pipes.
11886a
Diagram 12a.2
70mm
65mm
450 mm
225mm
20mm
Min. Clearance
70mm
232 mm
65mm
SIDE FLUE
REAR FLUE
L
L
Note :
Top of boiler
casing not
front panel
Note :
Top of boiler
casing not
front panel
* refer to diagram 6.1
11646
B
C
J
I
H
F
G
A
D
The flue kit 86285H is 810 mm long and comprises:
- Air duct pipe .......................................................... A
- Flue duct pipe ........................................................ B
- Elbow ....................................................................... C
- Fixing collar seal .................................................... D
- Fixing collar ..............................................................E
- External rubber sealing collar ............................... F
- Internal flange ....................................................... G
- Gasket ..................................................................... H
- Screws ....................................................................... I
- 'O' rings ..................................................................... J
Diagram 12a.1
E
Horizontal Top flue kit