6 boiler location, flue and ventilation – Glow-worm 30ci Plus User Manual
Page 15
15
4000123944-2
6 Boiler Location, Flue and Ventilation
Diagram 6.2
MINIMUM SITING DIMENSIONS FOR THE
POSITIONING OF FLUE TERMINALS
MM
HORIZONTAL FLUES
A
DIRECTLY BELOW, ABOVE OR
HORIZONTALLY TO AN OPENING, AIR BRICK,
OPENING WINDOWS, AIR VENT, OR ANY
OTHER VENTILATION OPENING
300
B
BELOW GUTTER, DRAIN/SOIL PIPE
75
C
BELOW EAVES
200
D
BELOW A BALCONY OR CAR PORT
200
E
FROM VERTICAL DRAIN PIPES AND
SOIL PIPES
150
F
FROM INTERNAL/EXTERNAL CORNERS
OR TO A BOUNDARY ALONGSIDE THE
TERMINAL
300
G
ABOVE ADJACENT GROUND OR
BALCONY LEVEL
300
H
FROM SURFACE OR A BOUNDARY
FACING THE TERMINAL
600
I
FACING TERMINALS
1200
J
FROM OPENING (DOOR/WINDOW)
IN CAR PORT INTO DWELLING
1200
K
VERTICAL FROM A TERMINAL
1500
L
HORIZONTALLY FROM A TERMINAL
300
VERTICAL FLUES
M
FROM ADJACENT WALL TO FLUE
300
N
FROM ANOTHER TERMINAL
600
P
FROM ADJACENT OPENING WINDOW
1000
Q
ABOVE ROOF LEVEL
300
11508
Diagram 6.3
6.2 Terminal guard, see diagram 6.3.
A terminal guard is required if persons could come into contact
with the terminal or the terminal could be subject to damage.
If a terminal guard is required, it must be positioned to provide
a minimum of 50mm clearance from any part of the terminal and
to be central over the terminal.
A suitable terminal guard type K3 can be supplied by:
Tower flue components Ltd.
Morley road
Tonbridge
Kent
TN9 1RA
6.3 Flue options
There are various flue systems to choose from as follows:
Horizontal telescopic rear flue pack.
Horizontal telescopic top flue pack.
Horizontal top flue pack.
Horizontal extended flue pack.
Vertical flue pack.
Twin flue pack.
Extensions, 90
°
and 45
°
bends.
For detailed information refer to flue options guide. This is
available from your nearest stockist.
6.4 Cupboard or compartment ventilation
The boiler can be fitted in a cupboard or compartment without
the need for permanent ventilation.