1 technical data, 30ci plus – Glow-worm 30ci Plus User Manual
Page 10
10
4000123944-2
The 30ci plus is delivered in two separate
packages:
• The boiler including fixing jig complete with
isolating valves and fittings.
• The flue system.
Diagram 1.1
Net lift weight (boiler only) 41 kg
Gross lift weight (boiler and packaging) 47 kg
1 Technical Data
11542a
365
232
798
450
Heat input (max) NET Q
32,6 kW
111,231 BTU/H
Heat input (min) NET Q
12,5 kW
42,650 BTU/H
Heat output (max) NET P
29,6 kW
100,995 BTU/H
Heat output (min) NET P
10,3 kW
35,144 BTU/H
Efficiency - Sedbuk D
79,6%
Maximum heating temperature
87
°
C
Expansion vessel effective capacity
8 litres
Expansion vessel charge pressure
0,5 bar
Maximum system capacity at 75
°
C
156 litres
Safety valve,
maximum service pressure 3 bar
Heating
Heat input (max) NET Q
32,6 kW
111,231 BTU/H
Heat input (min) NET Q
12,5 kW
42,650 BTU/H
Heat output (max) NET P
29,6 kW
100,995 BTU/H
Heat output (min) NET P
10,3 kW
34,155 BTU/H
Maximum hot water temperature
65
°
C
Minimum hot water temperature
38
°
C
Specific flow rate (for 35
°
C temp rise)
12,1 litres/min.
Threshold flow rate
1,7 litres/min.
Maximum supply pressure
10 bar
Minimum supply pressure
0,5 bar
Hot water
Electrical supply
230 V ~ 50Hz
Electrical rating
122 W fused at 3A
Level of protection
IPX4D
Fuse rating
1,25mA
Electrical
Products outlet diameter
60 mm
Fresh air inlet diameter
100 mm
Combustion products values
CO (40 ppm)
CO2 (7,6%)
NOx (81ppm)
Combustion
Ø Burner injector
1,2 mm
Inlet pressure
20 mbar
Maxi. Burner pressure
13,3 mbar
Mini. Burner pressure
2,15 mbar
Gas rate maximum
3,45 m
3
/h
Natural Gas (G20)
Ø Burner injector
0,73 mm
Inlet pressure
29 mbar
Maxi. Burner pressure
25,5 mbar
Mini. Burner pressure
4,7 mbar
Gas rate maximum
2,53 kg/h
Butane Gas (G30)
Ø Burner injector
0,73 mm
Inlet pressure
29 mbar
Maxi. Burner pressure
32,5 mbar
Mini. Burner pressure
4,7 mbar
Gas rate maximum
2,53 kg/h
Propane Gas (G31)
30ci plus