beautypg.com

EXFO OTDR 2 User Manual

Page 39

background image

Preparing Your OTDR for a Test

OTDR

31

Setting the Analysis Detection Thresholds

The following examples show how different splice-loss threshold levels
can affect the number of displayed events, especially small non-reflective
events such as those caused by two splices. Three traces are shown,
corresponding to three threshold level settings.

Threshold at 0.05 dB

With the threshold set to 0.05 dB, two events are displayed at distances
corresponding to the location of the first and second splices.

Threshold at 0.1 dB

Only the first splice is displayed, as the threshold is set to 0.1 dB and
the second splice loss is lower than 0.1 dB.

Threshold at 0.15 dB

The first two splices are not displayed, as the threshold is set to 0.15 dB
and the first and second splice losses are lower than 0.15 dB.

Thresholds values are saved with the measurement. It is possible to view
these thresholds values even if you open the file on another unit.

Event location

Threshold

at 0.05 dB

Threshold

at 0.1 dB

Threshold

at 0.15 dB

Second splice

First splice

Not displayed

Not
displayed